For more information about Standard Form Kits in general, please review ServiceForms Standard Form Kits - Introduction
Overview - Sprinkler Standard Form Kit
The Sprinkler Standard Forms Kit includes inspection, testing, and maintenance questions and is based on NFPA standards.
The forms included in the Sprinkler Standard Forms Kit:
- Dry Sprinkler Inspection & Testing
- Wet Sprinkler Inspection & Testing
- Deluge Sprinkler Inspection & Testing
- Pre-Action Sprinkler Inspection & Testing
- Standpipe Inspection & Testing
- Foam Sprinkler Inspection & Testing
- Water Storage Tank Inspection
- Fire Service Main Inspection & Testing
- Diesel Fire Pump Inspection & Testing
- Electric Fire Pump Inspection & Testing
Additional details:
Dry Sprinkler Inspection & Testing:
- Inspection intervals included: monthly, quarterly, semi-annually, annually, 3-year & 5-year.
- Asset Requirements:
- Asset - Dry Sprinkler (dry_sprinkler)
- Subasset - Dry Valve (dry_valve)
- Subasset - Control Valve (control_valve)
- Subasset - Main Drain Valve (main_drain_valve)
- Subasset - Sprinkler Supervisory Device (sprinkler_supervisory_device)
- Asset - Dry Sprinkler (dry_sprinkler)
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Wet Sprinkler Inspection & Testing:
- Inspection intervals included: monthly, quarterly, semi-annually, annually & 5-year.
- Asset Requirements:
- Asset- Wet Sprinkler (wet_sprinkler)
- Subasset - Control Valve (control_valve)
- Subasset - Main Drain Valve (main_drain_valve)
- Subasset - Sprinkler Supervisory Device (sprinkler_supervisory_device)
- Asset- Wet Sprinkler (wet_sprinkler)
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Deluge Sprinkler Inspection & Testing:
- Inspection intervals included: monthly, quarterly, semi-annually, annually & 5-year.
- Asset Requirements:
- Asset - Deluge Valve (deluge_valve)
- Subasset - Control Valve (control_valve)
- Subasset - Main Drain Valve (main_drain_valve)
- Subasset - Sprinkler Supervisory Device (sprinkler_supervisory_device)
- Asset - Deluge Valve (deluge_valve)
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Pre-Action Sprinkler Inspection & Testing:
- Inspection intervals included: monthly, quarterly, semi-annually, annually, 3-year & 5-year.
- Asset Requirements:
- Asset - Preaction Valve (preaction_valve)
- Subasset - Control Valve (control_valve)
- Subasset - Main Drain Valve (main_drain_valve)
- Subasset - Sprinkler Supervisory Device (sprinkler_supervisory_device)
- Asset - Preaction Valve (preaction_valve)
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Foam Sprinkler Inspection & Testing:
- Inspection intervals included: monthly, quarterly, semi-annually, annually, 5-year & 10-year.
- Asset Requirements:
- Asset - Foam System Suppression (foam_system_suppression)
- Subasset - Control Valve (control_valve)
- Subasset - Main Drain Valve (main_drain_valve)
- Asset - Foam System Suppression (foam_system_suppression)
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Standpipe Inspection & Testing:
- Inspection intervals included: monthly, quarterly, annually & 5-year.
- Asset Requirements:
- Asset - Standpipe (stand_pipe)
- Subasset - Control Valve (control_valve)
- Subasset - Main Drain Valve (main_drain_valve)
- Subasset - Standpipe Valve (standpipe_valve)
- Asset - Standpipe (stand_pipe)
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Water Storage Tank Inspection:
- Inspection intervals included: monthly, quarterly, semi-annually, annually, 2-year, 3-year & 5-year.
- Asset Requirements:
- Asset Water Tank (water_tank)
- Subasset - Control Valve (control_valve)
- Asset Water Tank (water_tank)
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Fire Service Main Inspection & Testing:
- Inspection intervals included: monthly, quarterly, semi-annually, annually & 5-year.
- Asset Requirements:
- Asset - Private Fire Hydrant (hydrant)
- Subasset - Control Valve (control_valve)
- Asset Requirements:
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Diesel Fire Pump Inspection & Testing:
- Inspection intervals included: weekly, monthly, quarterly, semi-annually, annually & 5-year.
- Asset Requirement:
- Asset - Fire Pump (fire_pump)
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Electric Fire Pump Inspection & Testing:
- Inspection intervals included: weekly, monthly, quarterly, semi-annually, annually & 5-year.
- Asset Requirement:
- Asset - Fire Pump (fire_pump)
- Deficiencies: Technicians record deficiencies in the mobile form. Deficiencies appear on the PDF output and automatically populate in your ServiceTrade account.
Download the PDF Report Example for the individual Sprinkler Standard Forms Kit:
- Diesel Fire Pump Inspection & Testing.pdf700 KB
- Electric Fire Pump Inspection & Testing.pdf700 KB
- Standpipe System Report Example.pdf200 KB
- Deluge Sprinkler Inspection & Testing -Example.pdf200 KB
- Foam Sprinkler Inspection & Testing Report Example.pdf200 KB
- Water Storage Tank Inspection Example.pdf100 KB
- Dry Sprinkler System Inspection & Testing Example.pdf200 KB
- PreAction Sprinkler Inspection & Testing Example.pdf200 KB
- Fire Service Main Inspection & Testing Report Example.pdf200 KB
- Wet Sprinkler Inspection & Testing Example.pdf200 KB
Comments
0 comments
Please sign in to leave a comment.